http://IEC/TC57/2017/EA_Model#ReferenceData.RegisteredGenerator
Class ReferenceData.RegisteredGenerator


type
Class [owl:Class]
comment
Model of a generator that is registered to participate in the market
subClassOf
MarketCommon.RegisteredResource
equivalentClass
RegisteredGenerator.pumpMinDownTime max 1 float
RegisteredGenerator.lowerRampRate max 1 Domain.ActivePowerChangeRate
RegisteredGenerator.pumpShutdownTime max 1 nonNegativeInteger
RegisteredGenerator.commericialOperationDate max 1 dateTime
RegisteredGenerator.raiseControlRate max 1 Domain.ActivePowerChangeRate
RegisteredGenerator.combinedCyclePlantName max 1 string
RegisteredGenerator.maxWeeklyStarts max 1 nonNegativeInteger
RegisteredGenerator.nameplateCapacity max 1 Domain.ActivePower
RegisteredGenerator.loadFollowingDownMSS max 1 YesNo
RegisteredGenerator.operatingMaintenanceCost max 1 Domain.CostPerEnergyUnit
RegisteredGenerator.maxPumpingLevel max 1 Domain.ActivePower
RegisteredGenerator.maxDependableCap max 1 Domain.ActivePower
RegisteredGenerator.intColdTime max 1 float
RegisteredGenerator.maxStartUpsPerDay max 1 nonNegativeInteger
RegisteredGenerator.RMRFlag max 1 FlagTypeRMR
RegisteredGenerator.maximumAllowableSpinningReserve max 1 Domain.ActivePower
RegisteredGenerator.highControlLimit max 1 Domain.ActivePower
RegisteredGenerator.minimumLoadFuelCost max 1 Production.CostPerHeatUnit
RegisteredGenerator.rampCurveType max 1 RampCurveType
RegisteredGenerator.pumpingCost max 1 Domain.CostRate
RegisteredGenerator.pumpShutdownCost max 1 float
RegisteredGenerator.useLimitFlag max 1 YesNo
RegisteredGenerator.regulationFlag max 1 nonNegativeInteger
RegisteredGenerator.intStartTime max 1 float
RegisteredGenerator.constrainedOutputFlag max 1 YesNo
RegisteredGenerator.lowControlLImit max 1 Domain.ActivePower
RegisteredGenerator.RMTFlag max 1 YesNo
RegisteredGenerator.RMRManualIndicator max 1 YesNo
RegisteredGenerator.mustOfferRA max 1 YesNo
RegisteredGenerator.intendedPIRP max 1 YesNo
RegisteredGenerator.maximumOperatingMW max 1 Domain.ActivePower
RegisteredGenerator.maxShutdownTime max 1 dateTime
RegisteredGenerator.maxMinLoadCost max 1 Domain.CostRate
RegisteredGenerator.minLoadCost max 1 Domain.CostRate
RegisteredGenerator.maxLayOffSelfSchedQty max 1 float
RegisteredGenerator.RMNRFlag max 1 YesNo
RegisteredGenerator.rampMode max 1 RampModeType
RegisteredGenerator.qualifyingFacilityOwner max 1 string
RegisteredGenerator.hotIntTime max 1 float
RegisteredGenerator.regulationRampRate max 1 Domain.ActivePower
RegisteredGenerator.spinReserveRamp max 1 Domain.ActivePowerChangeRate
RegisteredGenerator.operatingMode max 1 string
RegisteredGenerator.riverSystem max 1 string
RegisteredGenerator.pumpMinUpTime max 1 float
RegisteredGenerator.unitType max 1 UnitType
RegisteredGenerator.coldStartTime max 1 float
RegisteredGenerator.fuelSource max 1 FuelSource
RegisteredGenerator.maxWeeklyEnergy max 1 float
RegisteredGenerator.extremeLongStart max 1 YesNo
RegisteredGenerator.pumpingFactor max 1 float
RegisteredGenerator.quickStartFlag max 1 YesNo
RegisteredGenerator.resourceSubType max 1 string
RegisteredGenerator.costBasis max 1 CostBasis
RegisteredGenerator.capacityFactor max 1 Domain.PerCent
RegisteredGenerator.minimumOperatingMW max 1 Domain.ActivePower
RegisteredGenerator.loadFollowingUpMSS max 1 YesNo
RegisteredGenerator.syncCondCapable max 1 YesNo
RegisteredGenerator.proxyFlag max 1 YesNo
RegisteredGenerator.hotStartTime max 1 float
RegisteredGenerator.raiseRampRate max 1 Domain.ActivePowerChangeRate
RegisteredGenerator.lowerControlRate max 1 Domain.ActivePowerChangeRate
References