http://IEC/TC57/2017/EA_Model#ParticipantInterfaces.GeneratingBid
Class ParticipantInterfaces.GeneratingBid


type
Class [owl:Class]
comment
Offer to supply energy/ancillary services from a generating unit or resource
subClassOf
ParticipantInterfaces.ResourceBid
equivalentClass
GeneratingBid.lowerRampRate max 1 Domain.ActivePowerChangeRate
GeneratingBid.rampCurveType max 1 nonNegativeInteger
GeneratingBid.minimumEconomicMW max 1 float
GeneratingBid.installedCapacity max 1 float
GeneratingBid.startUpType max 1 nonNegativeInteger
GeneratingBid.startupCost max 1 float
GeneratingBid.maximumEconomicMW max 1 float
GeneratingBid.noLoadCost max 1 float
GeneratingBid.downTimeMax max 1 float
GeneratingBid.notificationTime max 1 float
GeneratingBid.raiseRampRate max 1 Domain.ActivePowerChangeRate
GeneratingBid.maxEmergencyMW max 1 Domain.ActivePower
GeneratingBid.upTimeMax max 1 float
GeneratingBid.minEmergencyMW max 1 Domain.ActivePower
GeneratingBid.operatingMode max 1 string
GeneratingBid.combinedCycleUnitOffer max 1 string
GeneratingBid.startUpRampRate max 1 Domain.ActivePowerChangeRate
References