http://IEC/TC57/2017/EA_Model#Metering.UsagePoint
Class Metering.UsagePoint


type
Class [owl:Class]
comment
Logical or physical point in the network to which readings or events may be attributed. Used at the place where a physical or virtual meter may be located; however, it is not required that a meter be present.
subClassOf
Core.IdentifiedObject
equivalentClass
UsagePoint.estimatedLoad max 1 Domain.CurrentFlow
UsagePoint.nominalServiceVoltage max 1 Domain.Voltage
UsagePoint.checkBilling max 1 boolean
UsagePoint.readRoute max 1 string
UsagePoint.isSdp max 1 boolean
UsagePoint.phaseCode max 1 PhaseCode
UsagePoint.ratedCurrent max 1 Domain.CurrentFlow
UsagePoint.readCycle max 1 string
UsagePoint.grounded max 1 boolean
UsagePoint.ratedPower max 1 Domain.ActivePower
UsagePoint.servicePriority max 1 string
UsagePoint.minimalUsageExpected max 1 boolean
UsagePoint.outageRegion max 1 string
UsagePoint.amiBillingReady max 1 AmiBillingReadyKind
UsagePoint.connectionState max 1 UsagePointConnectedKind
UsagePoint.isVirtual max 1 boolean
UsagePoint.serviceDeliveryRemark max 1 string
References

Generated with TopBraid Composer by TopQuadrant, Inc.