http://IEC/TC57/2017/EA_Model#Metering.PanDemandResponse
Class Metering.PanDemandResponse


type
Class [owl:Class]
comment
PAN control used to issue action/command to PAN devices during a demand response/load control event.
subClassOf
Metering.EndDeviceAction
equivalentClass
PanDemandResponse.heatingSetpoint max 1 Domain.Temperature
PanDemandResponse.coolingSetpoint max 1 Domain.Temperature
PanDemandResponse.heatingOffset max 1 Domain.Temperature
PanDemandResponse.avgLoadAdjustment max 1 Domain.PerCent
PanDemandResponse.coolingOffset max 1 Domain.Temperature
PanDemandResponse.appliance max 1 Metering.ControlledAppliance
PanDemandResponse.enrollmentGroup max 1 string
PanDemandResponse.cancelDateTime max 1 dateTime
PanDemandResponse.dutyCycle max 1 Domain.PerCent
PanDemandResponse.criticalityLevel max 1 string
PanDemandResponse.cancelControlMode max 1 string
PanDemandResponse.cancelNow max 1 boolean
References